Maintenance guide – Ver: 1.02
Like almost all machines, the Lapera DS requires a little maintenance every once and a while.
Daily
- Draw the equivalent of a shot or two of water through the group before making the first coffee of the day. This brings fresh water into the group and brew reservoir. Fresh water is a good thing. Allow the group a couple or three minutes to recover before pulling a shot.
- We recommend rinsing the portafilter under the faucet after each use. This is greatly facilitated by the bottomless portafilter.
Once in a while
- Clean the underside (the exposed side) of the shower screen and the bayonet (the inside of the grooves that hold the portafilter) with some paper towel, the ubiquitous and infinitely useful chopstick tool and a (dedicated) tooth brush.
Depending on usage, but typically between quarterly to semi-annually for daily domestic use:
- Clean or replace the shower screen and re-grease the piston seals. The instructions are below and there is a video of the full procedure here.
- Turn off the machine and let it cool
- Turn off the water supply
- Lower the lever to relieve any residual water pressure and return it to the upper position
- Unscrew and remove the lever handle
- Remove the group cover (two Phillips screws)
- (Optional – Replace the lever and pull it down and place it against the lower stop to raise the piston in the bore to aid with removal)
- Remove four M6 Allen (hex-drive) screws
- Pull the piston assembly up and out of the group
- Remove and clean the shower screen by pushing down on it firmly with a rolling pin or some other handy roughly cylindrical tool that wont scratch the bore or damage the screen. The first generation clip-on screens may require a little encouragement with an authoritative (but not extremely so) tap on the top of the rolling pin. Shower screens can be soaked overnight or boiled in dishwasher detergent to clean them. You should be able to see through the mesh when holding them up to the light.
- Re-grease seals and the inside of the piston bore with a very small quantity of food-safe silicon grease such as Molykote 111 – you really don’t need much, this is very much a case of less is more.
- Slide the piston assembly carefully back into the group and reassemble everything except for the shower screen.
- Turn the water supply back on and pull a little water through the group with a bowl held underneath it to catch the water that will spray everywhere without the shower screen installed.
- Depending on how much you applied, you may now see a few “worms” of grease protruding from the vents on the bottom of the piston. Wipe these off with a piece of paper towel.
- Turn on the machine and let it warm up and then check the vents for more “worms”.
- Either turn the machine back off again and let it cool, or, if you have asbestos fingers, reinstall the shower screen.
- Make coffee.
- Flushing the boiler – Even if you do not need to descale the machine, if you draw steam from the boiler, whatever mineral content there is in the water supply will be left behind in the boiler. Draining the boiler at regular intervals is therefore recommended (quarterly or semi-annually with daily use maybe – this really depends on your water supply). DO NOT open the drain valve while the machine is hot – doing so is dangerous and can damage the valve. Instead:
- Turn off the machine
- Allow it to cool below 70°C (which is still scalding hot – so be careful – but will not damage plastic waste-water plumbing).
- Remove the drip tray and locate the drain valve connected to the sump.
- Ensuring that the machine is below 70°C, open the drain valve and allow the boiler to drain completely.
- Close the drain valve and refill the machine as per the instructions in the installation guide.
Eventually sometime
- Replace the piston seals – The buna rubber piston seals will eventually dry out and the group will start to drip. The procedure for replacing the seals is here.
- Descaling – Depending on your water quality you may need to flush the entire hydraulic system (boiler, group and taps) with a descaling solution (3% citric acid by weight works well) at usage-dependent intervals. This is most easily done if you have a filter housing in line with the machine. Eventually, we will/may get around to posting some kind of instructional video on this… for now, you are on your own.Turn off the machine
Descaling – Depending on your water quality you may need to flush the entire hydraulic system (boiler, group and taps) with a descaling solution (3-10% food-grade citric acid by weight (30g-100g of powdered citric acid per liter of distilled or demineralized wtaer) depending on the level of scale) at usage-dependent intervals. This is best done if you have a filter housing in line with the machine.
- Turn off the machine
- Drain the boiler following the instructions in the boiler flushing section above.
- Fill the filter housing with citric acid aiming for 3-5% concentration once diluted. The boiler holds roughly 3 liters and the group is around 0.3L, so if the filter housing holds 1L, filling it with 9% citric acid will yield a approximately a 3% solution once diluted.
- Pull water through the the group until a dipped finger tastes like lemons and then fill the empty boiler. The tongue is an excellent tool for this :)
- Leave the acid in place for 20 minutes and then flush the group and the boiler with copious amounts of clean water until it no longer tastes like lemons. Instructions for refilling the boiler are in the installation guide. This may require quite a few flushes to acheive.
Maintenance guide – version history
2026 11 03 Ver: 1.02 – minor clarifications
2026 11 01 Ver: 1.01 – added descale procedure, corrections and rewrite for language
2022 10 02 Ver: 1.00